20 February, 2001 USING SERVICE PROGRAM MODES
5-29
Service
Tables
7
Mode Number/Name Function/[Setting]
Reset – Total Counter825
Resets the electrical total counter.
[0 = No / 1 = Yes]
• Usually, this is performed at installation. This SP mode
is effective only once, while the counter still has a
negative value. This SP mode cannot be used once the
counter takes a positive value.
• After selecting “1”, press the Original Type key and the
OK key (or ' key) at the same time to execute the
reset. If the reset Is successful, the display shows
“Action completed.” If the reset fails, the display shows
“Error!!!”.
Display – SC History901*
Displays the last twenty SC codes that have occurred.
[0 = No / 1 = Yes]
Clear – SC History902
Clears the SC history.
[0 = No / 1 = Yes]
After selecting “1”, press the Original Type key and the
OK key (or ' key) at the same time to execute the reset.
If the reset is successful, the display shows “Action
completed.” If the reset fails, the display shows “Error!!!”.
Display – Paper Jam History903*
Displays the paper jam history.
[0 = No / 1 = Yes]
Clear - Copy Jam History904
Clears the copy jam history.
[0 = No / 1 = Yes]
After selecting “1”, press the Original Type key and the
OK key (or ' key) at the same time to execute the reset.
If the reset is successful, the display shows “Action
completed.” If the reset fails, the display shows “Error!!!”.
Display - Original Jam History905*
Displays the original jam history.
[0 = No / 1 = Yes]
Clear - Original Jam History906
Clears the original jam history.
[0 = No / 1 = Yes]
After selecting “1”, press the Original Type key and the
OK key (or ' key) at the same time to execute the reset.
If the reset is successful, the display shows “Action
completed.” If the reset fails, the display shows “Error!!!”.
Reset - Timer Counter907
Resets the timer counter (SP7-991).
[0 = No / 1 = Yes]
After selecting “1”, press the Original Type key and the
OK key (or ' key) at the same time to execute the reset.
If the reset is successful, the display shows “Action
completed.” If the reset fails, the display shows “Error!!!”.