5.6 Motor-current connecon - 3-wire [RLS]
RW45
RW241/242
Connect all safety switches (ES21/22) and duty switches (ES11/12).
This is necessary for safety and correct funconal operaon.
RLS connecons: 1–6
Do NOT connect 1-phase electric motors (EM), that have motor-
current connecon through the RLS limit-switch system, in PARALLEL.
This prevents the risk of incorrect control, an incorrect direcon-of-
rotaon or incorrect operaon of limit-switch systems of dierent
electric motors.