Remote Commands for the I/Q Analyzer
R&S
®
FSWP
84User Manual 1177.5856.02 ─ 07
Example:
INST:CRE:REPL 'PhaseNoise',PNO,'PNO2'
Replaces the channel named "PhaseNoise" by a new channel of
type "Phase Noise" named "PNO2".
Usage: Setting only
INSTrument:DELete <ChannelName>
This command deletes a channel.
If you delete the last channel, the default "Phase Noise" channel is activated.
Setting parameters:
<ChannelName> String containing the name of the channel you want to delete.
A channel must exist in order to be able delete it.
Example:
INST:DEL 'PhaseNoise'
Deletes the channel with the name 'PhaseNoise'.
Usage: Setting only
INSTrument:LIST?
This command queries all active channels. This is useful in order to obtain the names
of the existing channels, which are required in order to replace or delete the channels.
Return values:
<ChannelType>,
<ChannelName>
For each channel, the command returns the channel type and
channel name (see tables below).
Tip: to change the channel name, use the INSTrument:
REName command.
Example:
INST:LIST?
Result for 2 channels:
'PNO','PhaseNoise','PNO','PhaseNoise2'
Usage: Query only
Table 8-2: Available channel types and default channel names
Application <ChannelType> Parameter Default Channel Name*)
Phase Noise PNOISE Phase Noise
Spectrum Monitor SMONitor Spectrum Monitor
Spectrum (R&S FSWP-B1) SANALYZER Spectrum
I/Q Analyzer (R&S FSWP-
B1)
IQ IQ Analyzer
Pulse Measurements
(R&S FSWP-K6)
PULSE Pulse
Analog Demodulation
(R&S FSWP-K7)
ADEM Analog Demod
Note: the default channel name is also listed in the table. If the specified name for a new channel already
exists, the default name, extended by a sequential number, is used for the new channel.
Activating I/Q Analyzer Measurements