Remote Commands for the I/Q Analyzer
R&S
®
FSWP
105User Manual 1177.5856.02 ─ 07
CALCulate<n>:MARKer<m>:Y
Suffix:
<n>
.
1..n
<m> 1..n
Return values:
<Result> Default unit: DBM
Manual operation: See " Marker Table " on page 17
See " Marker Peak List " on page 18
MMEMory:STORe<n>:LIST
<FileName>
This command exports the SEM and spurious emission list evaluation to a file.
The file format is *.dat.
Suffix:
<n>
.
Window
Parameters:
<FileName> String containing the path and name of the target file.
Example:
MMEM:STOR:LIST 'test'
Stores the current list evaluation results in the test.dat file.
8.6 Configuring I/Q Analyzer Measurements
Configuring Input Sources.....................................................................................105
Configuring Outputs.............................................................................................. 110
Configuring Level Characteristics..........................................................................111
Configuring the Attenuator.................................................................................... 113
Configuring the Preamplifier..................................................................................114
Scaling the Y-Axis..................................................................................................115
Configuring the Frequency....................................................................................118
Configuring Trigger................................................................................................119
Configuring Trigger Output....................................................................................124
Configuring Gated Measurements........................................................................ 126
Configuring Data Acquisition.................................................................................128
Automatic Configuration........................................................................................136
Configuring the Result Display..............................................................................139
8.6.1 Configuring Input Sources
INPut<ip>:ATTenuation:PROTection:RESet.......................................................................106
INPut<ip>:COUPling.......................................................................................................106
INPut<ip>:FILE:PATH..................................................................................................... 106
INPut<ip>:FILTer:HPASs[:STATe].....................................................................................107
INPut<ip>:FILTer:YIG[:STATe]..........................................................................................107