EasyManua.ls Logo

Rohde & Schwarz ZVL series - Page 314

Rohde & Schwarz ZVL series
624 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R&S ZVL GUI Reference
SETUP Key
Operating Manual 1303.6580.32-06
299
The Advanced LAN Configuration parameters are used as follows:
The Negotiation configuration field provides different Ethernet speed and duplex mode settings. In
general, the Auto Detect mode is sufficient.
ICMP Ping must be enabled to use the ping utility.
VXI-11 is the protocol that is used for discovery of the instrument in the LAN. According to the
standard, LXI devices must use VXI-11 to provide a discovery mechanism; other additional
discovery mechanisms are permitted.
Ping
Ping is a utility that verifies the connection between the analyzer and another device. The ping command
uses the ICMP echo request and echo reply packets to determine whether the LAN connection is
functional. Ping is useful for diagnosing IP network or router failures.
The ping utility is not password-protected. To initiate a ping between the analyzer and a second connected
device,
Enable ICMP Ping on the Advanced LAN Configuration page (enabled after an LCI).
Enter the IP address of the second device without the ping command and without any further
parameters into the Destination Address field (e.g. 10.113.10.203).
Click Submit.

Table of Contents