47
2
Basic
Operation
Switch Off
Switch Off
WARNING
When output is not being performed, remove any loaded media or switch
off the sub power.
The continued application of heat at a single location may cause the release
of toxic gases from the media or pose a re hazard.
Procedure
Hold down the sub power button for one
second or longer.
The sub power is switched o. Switch o the sub
power after output is nished.
Raise the loading lever (front).
When not using the machine, raise the loading lever
even if the sub power is on.
Leave the main power switched on at all times.
Never switch o the main power. By switching on the main power, the automatic maintenance function
is carried out periodically. If the automatic maintenance is not carried out, it may result in breakdown
of this machine such as breakdown of the print heads.
Never switch off the main power or unplug the power cord suddenly while opera-
tion is in progress.
Switching o the main power or unplugging the power cord suddenly while operation is in progress
may damage the print heads. Be sure to rst switch o the sub power. If the main power is accidentally
switched o, immediately turn the main and sub power back on.