Messages and Error Messages
 
This section lists the messages (error messages) that the TD-12 produces and explains the meaning of each 
message, giving you the appropriate action to take.
 
fig.Message_70
 
When an indication of “ACCEPT” is shown above [F5] as in the 
figure, pressing that button will close the message window.
 
Error Messages
 
Message
Meaning Action
 
Backup Battery Low!
The internal backup battery of the TD-12 (a 
battery that maintains data in the user mem-
ory) has run down.
Contact your dealer or a nearby Roland service 
center to have the battery replaced.
Backup NG! Data in the TD-12’s memory may be corrupt-
ed. The TD-12’s internal backup battery (the 
battery used for saving User memory data) is 
fully drained; internal data has been lost.
Contact your dealer or a nearby Roland service 
center to have the battery replaced. Follow the 
messages appearing on the screen to carry out 
Factory Reset (p. 79); you will then be able to 
use the unit temporarily.
MIDI Communication Error! It is possible that the power has been turned 
off for the MIDI device connected to the TD-
12’s MIDI IN connector.
Check the power of the connected MIDI de-
vice.
System Error! A problem has occurred with the internal 
system.
Contact your dealer or a nearby Roland service 
center.
Measure Maximum! The maximum number of measures that can 
be recorded to one pattern has been exceed-
ed; no further recording or editing that adds 
measures can be carried out.
Delete unneeded measures from the pattern 
being recorded or edited (p. 69).
Data Overload! Pattern contained an excessive amount of da-
ta, and as a result could not be output suc-
cessfully from MIDI OUT.
Try eliminating a part that has too much data.
Not Enough Memory! Pattern recording or editing could not be car-
ried out because there was not enough inter-
nal memory.
Try deleting patterns that are no longer needed 
(p. 69).
BULK DUMP
Checksum Error!
The checksum value of a system exclusive 
message was incorrect.
Correct the checksum value.
BULK DUMP
Receive Address Error!
The receive address of a system exclusive 
message was incorrect.
Correct the receive address.
BULK DUMP
Receive Data Error!
A MIDI message was received incorrectly. If the same error message is displayed repeat-
edly, there is a problem with the MIDI messag-
es that are being transmitted to the TD-12.
BULK DUMP
Receive Time Out!
The interval in receiving system exclusive 
messages were too long.
Make the interval of the data shorter.