Cleaning the Wiper Tray
Discharged uid collects in the wiper tray. The wiper tray must be cleaned periodically.
If the following message is displayed, clean the wiper tray, and then replace the tray pad.
CAUTION
Be sure to perform operaons as specied by the instrucons, and never touch any area
not specied in the instrucons.
Otherwise sudden movement of the machine may cause injury.
Required items
Tray pad Tweezers
Procedure
1. Press [ENTER].
2. Press [MENU].
3. Press [▼] several mes to display the screen shown below.
4. Press [▶] once, and then press [▼] several mes to display the screen shown below.
5. Press [▶] once, and then press [▼] several mes to display the screen shown below.
6. Press [ENTER].
7. When the screen shown below appears, remove the drain bole and discard the discharged uid.
IMPORTANT
When you remove the drain bole, a few drops of discharged uid may come out of the machine. Exercise cauon to prevent
this uid from soiling your hands or the oor.
CAUTION
Before you detach the drain bole, be sure to wait for the screen to display "EMPTY
DRAIN BOTTLE." Aer discarding the discharged uid, promptly aach the drain bot-
tle to the machine.
Failing to follow this procedure may cause discharged uid to ow out of the tube and spill, soiling
your hands or the oor.
WARNING
Never place discharged uid or ink near an open ame.