RootWave Pro User Guide
13. Move the Treatment Return
The Treatment Return Blade should be
re-sited regularly and at least every
hour to avoid it getting too hot.
It may also be necessary to move the
Treatment Return to reach target
treatment areas.
To withdraw the Treatment Return:
1. Before moving the Treatment Return, safe stop the Treatment
Lance, turn the power isolator switch on the Power Module to
‘Off’ and turn off the generator.
2. Disconnect both treatment cables and lay them on dry ground.
3. Unscrew the Treatment Return and place it on one side. Clean out
any debris from the thread.
4. Withdraw the Treatment Return Blade from the ground. If the
soil is loose then the Treatment Return Blade may be withdrawn
from the ground easily. Alternatively, you can use the extraction
handle or a spade to help free it from firm ground:
- To use the extraction handle, screw the handle fully into the
Treatment Return Blade, wiggle from side to side and pull.
- To use a spade, insert the spade into the ground about 5cm
from the face of the Treatment Return Blade at an angle of about
45 degrees, then push the spade in towards the Treatment Return
Blade, and the spade handle down towards the ground, to catch
the lip on the Treatment Return Blade and lever it out of the
ground.
To re install the Treatment Return see steps 4 and 5.