Poultry House Control
20
Standard Mode Programming Steps
operate or turn off when
reaching their ON temp.
1.2
Control |
Temperature
and Humidity
1. Assign Set Temperatures by bird
age (growth day).
2. Assign Low and High
Temperature Alarm Settings by
bird age.
3. Humidity Levels are for future use.
Precision Mode offers Humidity
Treatment.
1. Platinum Plus calculates
temperatures between those
you enter if ‘Curve On’ is
set in Control Mode.
2. See Management | Alarm
Setting, with Advanced
Alarms On to set
individual sensor alarms
(zone alarms).
1.3
Control |
Minimum
Ventilation
Timer
Set Minimum Ventilation Timer for
up to 10 different bird ages.
You may choose to turn on Minimum
Ventilation Curve in Control, Control
Mode Menu. Then Platinum Plus will
calculate intermediate cycle times.
Special Circumstance: Min Vent by
Curtains instead of Fans
1. Minimum Vent (Power) set to NO
in Install | Setup.
2. Natural Ventilation set to YES in
Install | Setup.
3. No Min Vent Timer assigned in
Control | Temp & Timer Settings.
1. For new growers,
recommend setting safe
ventilation timers for all
bird ages.
2. Advanced growers may
prefer to set min vent
timers daily. If so, use only
the 1
st
line so it is easy to
adjust.
3. Min Vent Timers run on
Timer BELOW the OFF
setting.
Special Circumstance: if set
this way, Control | Min Vent
Timer menu shows curtain
purge times instead of fan
cycle times.
1.4
Control |
Timer Settings
Set up to 4 independent cycle timers.
Assign particular cycle timers in Temp
& Timer Settings Menu above.
Devices assigned an auxiliary
timer run on cycle timer above
their ON temperature.