82
Heading
AA
USA – hazardous Area
FM. Class 1, Division 1, Groups C, D, E, F, G hazardous areas.
Factory Mutual - Explosionproof to NEC Article 500.
Temperature -30°C to +60°C (-22°F to +140°F).
*Option -40°C to +60°C (-40°F to +40°F).
*Alternative for Group B hazardous area. Temperatures as for Groups C and D.
Canada – hazardous Area
CSA EP. Class 1, Division 1, Groups C and D hazardous areas.
Canadian Standard Association - Explosionproof
Temperature -30°C to +70°C -22°F to +158°F).
*Option -50°C to +40°C (-58°F to +104°F).
*Alternative for Group B hazardous area. Temperatures as for Groups C and D.
International Non hazardous
WT: Standard watertight, BS EN 60529 :1992, IP68, 7 metres/72 hours.
Temperature -30°C to +70°C (-22°F to +158°F).
*Option -40°C to +70°C (-40°F to +158°F).
*Option -50°C to +40°C (-58°F to +104°F).
US – Non hazardous
NEMA 4, 4X and 6.
Temperature -30°C to +70°C (-22°F to +158°F).
*Option -40°C to +70°C (-40°F to +158°F).
*Option -50°C to +40°C (-58°F to +104°F).
Canada – Non hazardous
CSA WT: Canadian Standard Association –Watertight.
Wiring and components complying with CSA Enclosure 4 and 4X.
Temperature -30°C to +70°C (-22°F to +158°F).
*Option -40°C to +70°C (-40°F to +158°F).
*Option -50°C to +40°C (-58°F to +104°F).
Rotork can supply actuators to national standards not listed above.
For details please contact Rotork.
82
European – Hazardous area
ATEX (94/9/EC) II 2 GD c
Ex d IIB T4 Gb, Ex tb IIIC T120°C Db IP68
Temperature -20 to +70°C (-4 to +158°F)
*Option -30 to +70°C (-22 to +158°F), *Option -40 to +70°C (-40 to +158°F),
*Option -50 to +40°C (-58 to +104°F)
Ex d IIC T4 Gb, Ex tb IIIC T120°C Db IP68
Temperature -20 to +70°C (-4 to +158°F)
*Option -30 to +70°C (-22 to +158°F), *Option -40 to +70°C (-40 to +158°F),
*Option -50 to +40°C (-58 to +104°F)
Ex de IIB T4 Gb, Ex tb IIIC T120°C Db IP68
Temperature -20 to +70°C (-4 to +158°F)
*Option -30 to +70°C (-22 to +158°F), *Option -40 to +70°C (-40 to +158°F),
*Option -50 to +40°C (-58 to +104°F)
Ex de IIC T4 Gb, Ex tb IIIC T120°C Db IP68
Temperature -20 to +70°C (-4 to +158°F)
*Option -30 to +70°C (-22 to +158°F), *Option -40 to +70°C (-40 to +158°F),
*Option -50 to +40°C (-58 to +104°F)
International – Hazardous area
IEC. Exd IIB T4
IEC60079-0 and IEC60079-1 for Exd IIB T4
Temperature -20 to +70°C (-4 to +158°F)
*Option -30 to +70°C (-22 to +158°F), *Option -40 to +70°C (-40 to +158°F),
*Option -50 to +40°C (-58 to +104°F)
IEC. Exd IIC T4
IEC60079-0 and IEC60079-1 for Exd IIC T4
Temperature -20 to +70°C (-4 to +158°F)
*Option -30 to +70°C (-22 to +158°F), *Option -40 to +70°C (-40 to +158°F),
*Option -50 to +40°C (-58 to +104°F)
3 IQT Approvals
13
Refer to actuator nameplate for unit specific approval details