OPTIO
N NO.
MENU ITEM
Description
8.1.10Environment VariablesSets application environment variables.
8.2TECHNICAL
FEATURES
8.2.1Components testAllows the appliance's main components to be checked.
The components that can be checked are displayed.
Choose the component to be checked.
BREWING UNIT
Starts moving the brewing unit.
Compressor
The compressor is activated for a few seconds.
PUMPS
The pump selected is activated for a few seconds.
During the test, hot water is dispensed: do not put your hands in the dispensing area.
8.2.2Machine input
verification
Displays the status of the appliance's various sensors and/or controls (probes, microswitches,...).
For devices with ON/OFF functions, the status is shown using colour: green is used if the appliance is active/actuated, and red is used if it is
disabled/not actuated.
For the sensors, the detected value is displayed (e.g. the temperature).
8.2.3Output TestAllows the operation of the appliance's various components to be checked.
The components that can be checked are displayed.
Choose the component to be tested.
For safety reasons, the tests must be carried out with the door closed.
Press and hold down the component button to activate it and check that it is working.
When the button is released, the component will be turned off.
8.2.4Touch screen testAllows the touch operation to be checked.
Tap and drag your finger across the touchscreen.
Each tap leaves a different-coloured trace.
8.2.5Emptying the boilerThe heating unit can be emptied.
8.2.6Verification machine
parameters
Not available.
8.2.7Complete selectionsDispenses all the beverages for test purposes.
8.2.8Automatic testAcquires scripts that allow automatic testing.
8.2.9Reset to first Power
On
Allows the appliance to be restored to its factory settings.
All the statistical data, fault lists and settings will be lost.
8.2.10Reboot systemProgrammes the system reboot.
8.3Date/Time SettingsThe date and time are used to record events (for example faults,...), manage programmed washes and produce maintenance warnings.
Set the current date and time.
8.4LanguagesThe predefined language used to display messages on the user interface and in the menus can be changed.
Some languages are available for the "change language" function.
8.5User profilesThe use of some programming functions can be enabled/disabled via the access profiles.
The access profile ensures that only the functions linked to it can be used.
Each user profile has an access password.
The default passwords are:
- Technician (4444),
- User (1111)
Advanced programming functions must only be used by people with specific knowledge of the appliance (technical personnel) and hygiene
regulations.
It is possible to change the access password for each user profile from this function;
tap the keypad icon to change the password.
8.6NetworkThe network configurations vary depending on the network selected and the network protections adopted.
8.6.1Wi-FiIt allows the Wi-Fi connection of the appliance to be enabled and configured.
Enable the Wi-Fi connection to connect the appliance to a Wi-Fi network.
The appliance supports the main Wi-Fi protection systems (cryptography).
"Open" encryption does not guarantee any type of protection.
By activating the Wi-Fi connection, the appliance displays the Wi-Fi networks available.
Choose the name of the Wi-Fi network (SSID) to which to be connected; should the Wi-Fi network be hidden it is necessary to know the name
(SSID) and enter it manually.
The network parameters (such as the IP address,...) can either be:
- assigned automatically (DHCP)
or
- manually.
To automatically assign the network parameters, there must be a DHCP server on the network.
The parameters relative to the protections and the access password to the Wi-Fi network must be set manually.
The MAC address is a unique address assigned by the manufacturer that identifies the appliance's network card.
The MAC address cannot be changed.
8.6.2BLUETOOTHIt enables and configures the Bluetooth connection and allows short-range data exchange (a maximum of 10 metres) between the appliance and
other devices.
To connect to a Bluetooth device you need to:
- enter the identification of the appliance.
- Make the appliance detectable when searching for Bluetooth devices. In detection mode, a wireless signal is transmitted which allows the
appliance to be detected by other devices.
- Enter the authentication code in order to be able to associate the Bluetooth device.
When a device can be detected, the pairing mode is also usually enabled.
The linked devices are shown.
From the menu it is possible to enable the connection with Blue Manager, an application which permits the downloading of statistics via Bluetooth
using the EVOCA proprietary application BlueRed Manager available on Play Store.
8.8InformationAllows all of the information regarding the appliance's software to be viewed (version, graphic theme used, machine configuration, etc.).