EasyManua.ls Logo

Sailor H2095C - Page 75

Sailor H2095C
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System Installation
System InstallationSystem Installation
System Installation TT-3608G Printer Unit
TT-3608G Printer UnitTT-3608G Printer Unit
TT-3608G Printer Unit
Page
PagePage
Page 3-40
3-403-40
3-40 25-Jul-00
25-Jul-0025-Jul-00
25-Jul-00
The Arcnet bus will have two ends and both of these should be
terminated with a 100 Ohm resistor (± 1%). The TT-3608G
does NOT contain any termination-resistor. If needed the ter-
mination resistor could be placed in the 15 pole SubD con-
nector connected to the twisted pair cable. This is the case for
the accompanying cable.
Always use shielded twisted pair cables and shielded con-
nectors (otherwise the EMC specifications are not guarantied
to be fulfilled).
The length of the cable making up the Arcnet bus should be
no longer than 100 meters.
Minimum spacing between devices connected to the Arcnet
bus is 2 meter of cable.
No more than 8 Arcnet devices (including transceiver) must
be connected to the Arcnet bus.