56
-
8000B Series
Function
Code
Function Descriptions
Minimum
Unit
Factory
Setting
Modi-
cation
Type
FA.01
Motor over load
protection
20. 0%~12 0.0 % (m oto r rat ed
current)
0.1% 100.0%
FA.02
Threshold of
trip-free
70.0%~110.0% (standard bus
voltage)
0.1% 80.0%
FA.03
Decrease rate
of trip-free
0.00Hz~F0.10 0.01Hz 0.00Hz
FA.04
Over-voltage
stall protection
0:Disabled
1:Enabled
0
FA.05
Over-voltage
stall protection
point
110~150% 1% 120%
FA.06
Auto current
limiting level
50~200% 1% 160%
FA.07
Frequency
decrease rate
when current
limiting
0.00~50.00Hz/s 0.01Hz/s 10.00Hz/s
FA.08
Auto current
limiting
selection
0:Enabled
1: Disabled at constant speed
1
FA.09
Fault auto reset
times
0~3 0
FA.10
Fault auto reset
interval
0.1~100.0s 0.1s 1.0s
FA.11 Reserved
FA.12
Phase-lack
protection of
input
0:Disabled
1:Enabled
1
FA.13
Phase-lack
protection of
output
0: Disabled
1:Enabled
1