EasyManuals Logo
Home>SAJ>Inverter>8000B series

SAJ 8000B series User Manual

SAJ 8000B series
75 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #61 background imageLoading...
Page #61 background image
-
58
-
8000B Series
Function
Code
Function Descriptions
Minimum
Unit
Factory
Setting
Modi-
cation
Type
FA.18
Output current
when fault
occurs
A
FA.19
DC bus voltage
when fault
occurs
V 0.0V
FA.20
Input terminal
status when
fault occurs
0
FA.21
Output terminal
status when
fault occurs
0
FB Group: Swing Frequency and Counting Meter Parameters
FB.00
Swing
frequency
bandwidth
0.0~100.0% (relative to setting
frequency)
0.1% 0.0%
FB.01
Skip frequency
bandwidth
0.0 ~ 50.0% (relative to swing
frequency bandwidth)
0.1% 0.0%
FB.02
Rising time
of swing
frequency
0.1~3600.0s 0.1s 5.0s
FB.03
Dropping
time of swing
frequency
0.1~3600.0s 0.1s 5.0s
FB.04
Counting meter
method
0:Start from zero when power on
1:Start from counting meter of
the last time
0.1s 5.0s
FB.05
Roller perimeter
of counting
meter
0~9999cm 1cm 100cm
FB.06
Setting value of
counting meter
0~9999m 1m 1000m

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SAJ 8000B series and is the answer not in the manual?

SAJ 8000B series Specifications

General IconGeneral
BrandSAJ
Model8000B series
CategoryInverter
LanguageEnglish

Related product manuals