58
-
8000B Series
Function
Code
Function Descriptions
Minimum
Unit
Factory
Setting
Modi-
cation
Type
FA.18
Output current
when fault
occurs
A
FA.19
DC bus voltage
when fault
occurs
V 0.0V
FA.20
Input terminal
status when
fault occurs
0
FA.21
Output terminal
status when
fault occurs
0
FB Group: Swing Frequency and Counting Meter Parameters
FB.00
Swing
frequency
bandwidth
0.0~100.0% (relative to setting
frequency)
0.1% 0.0%
FB.01
Skip frequency
bandwidth
0.0 ~ 50.0% (relative to swing
frequency bandwidth)
0.1% 0.0%
FB.02
Rising time
of swing
frequency
0.1~3600.0s 0.1s 5.0s
FB.03
Dropping
time of swing
frequency
0.1~3600.0s 0.1s 5.0s
FB.04
Counting meter
method
0:Start from zero when power on
1:Start from counting meter of
the last time
0.1s 5.0s
FB.05
Roller perimeter
of counting
meter
0~9999cm 1cm 100cm
FB.06
Setting value of
counting meter
0~9999m 1m 1000m