EasyManuals Logo
Home>SAJ>Inverter>8000B series

SAJ 8000B series User Manual

SAJ 8000B series
75 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
-
36
-
8000B Series
Chapter 5 Function Code Table
Notice:
:
The parameters can be modied at stop or running status.
:
The parameters cannot be modied at running status.
:
The parameters which are actual-detecting record value cannot be modied.
Function
Code
Function Descriptions
Minimum
Unit
Factory
Setting
Modi-
cation
Type
F0 Group: Basic Parameters
F0.00
Control mode
selection
0: Sensorless vector control
1:V/F control
1
F0.01
Run command
source
0:Keypad
1:Terminals
2: Communications (RS485)
0
F0.02
Setting value
valid or not
of keypad /
terminals
0: Valid and saved when power-
off
1:Valid a nd n ot s av ed w he n
power-off
2: Invalid
3 . Va l i d a t r u n n i n g s t a t u s .
Changed into the setting value
of F0.08 when restart after stop.
0
F0.03
Master
frequency
setting source X
0: Up/down key
1: Potentiometer of panel
2: AVI terminal
3: ACI terminal
4: Reserved
5: Reserved
6: Multi-function digital input
terminals
7: PLC
8: PID
9: Communication interface
1
F0.04
Auxiliary
frequency
setting source Y
0: AVI terminal
1: ACI terminal
2: Reserved
1