Page #40 background image
-
37
-
8000B Series
Function
Code
Function Descriptions
Minimum
Unit
Factory
Setting
Modi-
cation
Type
F0.05
Range of
auxiliary
frequency
setting source Y
0 : R e l a t i v e t o t h e m a x i .
frequency
1: Relative to master frequency
setting source X
0
F0.06 Reserved
F0.07
Frequency
setting source
selection
0:X
1: Y
2: X and Y
3: Max. value of (X, Y)
0
F0.08
Keypad setting
frequency
0.00Hz~ F0.10 0.01Hz 50.00 Hz
F0.09
Running
direction
selection
0: Forward
1: Reverse
2: Reverse running prohibited
0
F0.10
Max. output
frequency
10.00~600.00Hz 0.01Hz 50.00Hz
F0.11
Upper limit
frequency
setting source
0:Keypad (F0.12)
1:AVI terminal
2: ACI terminal
3: Multi-function digital input
terminals
4: Communication interface
0
F0.12
Upper limit
of running
frequency
F0.14~ F0.10 0.01Hz 50.00Hz
F0.13 Reserved
F0.14
Lower limit
of running
frequency
0.00Hz~ F0.12 0.01Hz 0.00Hz