55
-
8000B Series
Function
Code
Function Descriptions
Minimum
Unit
Factory
Setting
Modi-
cation
Type
F9.07
Sampling cycle
(T)
0.01~100.0s 0.01s 0.10s
F9.08
Bias limit of PID
control
0.0~100.0% 0.1% 0.0%
F9.09
Feedback lost
detecting value
0.0~100.0% 0.1% 0.0%
F9.10
Feedback lost
detecting time
0.0~3600.0s 0.1s 1.0s
F9.11
PID sleep
function option
0: PID normal working
1: PID sleep
0
F9.12
PID sleep
detecting delay
time
0.0~3600.0s 0.1s 3.0s
F9.13
PID wake-up
threshold
0.0~100.0% 0.1% 0.0%
F9.14
PID wake-up
detecting delay
time
0.0~3600.0s 0.1s 3.0s
F9.15
Lower
frequency
of PID sleep
detecting
0.00Hz~20.00Hz 0.01Hz 10.00Hz
F9.16
~
F9.18
Reserved
FA Group: Protection and Malfunction Parameters
FA.00
Motor overload
protection
0:Disabled
1:Normal motor with low speed
compensation
2:Va r i ab l e f req u enc y m o to r
without low speed compensation
2