EasyManua.ls Logo

SAJ 8000B series - FD Group: Multi-Step Speed and Simple PLC Parameters

SAJ 8000B series
75 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-
60
-
8000B Series
Function
Code
Function Descriptions
Minimum
Unit
Factory
Setting
Modi-
cation
Type
FC.04
Communication
timeout fault
time
0.0 (invalid), 0.1~100.0s 0.1s 0.0s
FC.05
Dispose of
communication
timeout fault
0:Alarm and coast to stop
1:No alarm and continue to run
2:No alarm but stop according to
F1.05 (only when F0.01= 2)
3: No alarm but stop according
to F1.05
1
FC.06
Transmission
response action
Unit’s digit:
0: Response to writing
1: No response to writing
Ten’s place:
0:Value not saved when power-
off
1: Value saved when power-off
0
FD Group:Multi-step Speed and Simple PLC Parameters
FD.00
Simple PLC
operation
method
0:Stop after operation once time
1:K ee p the f i na l va lu e af te r
operation once time
2:Operation in cycles
0
FD.01
Memory option
of simple PLC
when power-off
0: Invalid
1:Valid
0
FD.02
Multi- step
speed 0
-100~100% 0.1% 0.0%
FD.03
0
th
step running
time
0.0~6553s(m) 0.1s(m) 0.0s
FD.04
Multi- step
speed 1
-100~100% 0.1% 0.0%
FD.05
1
st
step running
time
0.0~6553s(m) 0.1s(m) 0.0s

Table of Contents

Related product manuals