EasyManuals Logo
Home>SAJ>Inverter>8000B series

SAJ 8000B series User Manual

SAJ 8000B series
75 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #41 background imageLoading...
Page #41 background image
-
38
-
8000B Series
Function
Code
Function Descriptions
Minimum
Unit
Factory
Setting
Modi-
cation
Type
F0.15
The function
of lower limit
frequency
0 : R u n n i n g a t l o w e r l i m i t
frequency
1: Stop frequency point
2: Sleep frequency point
0
F0.16
Carrier
frequency
1.0~15.0kHz 1kHz
Different
according
to the
inverter
type
F0.17
PWM mode
selection
0:PWM mode 1
1:PWM mode 2
2:PWM mode 3
0
F0.18
Acceleration
time 1
0.1~3600.0s 0.1s
Different
according
to the
inverter
type
F0.19
Deceleration
time 1
0.1~3600.0s 0.1s
Different
according
to the
inverter
type s
F0.20 Default setting
0:No operation
1: Restore to factory setting
2:Fault record clearing
0
F0.21
Parameter lock
setting
0: Unlock parameter
1: Lock parameter
0
F0.22
Acceleration/
deceleration
method
0: Linear method
1: Reserved
0
F0.23 Reserved
F0.24 Reserved

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SAJ 8000B series and is the answer not in the manual?

SAJ 8000B series Specifications

General IconGeneral
BrandSAJ
Model8000B series
CategoryInverter
LanguageEnglish

Related product manuals