38
-
8000B Series
Function
Code
Function Descriptions
Minimum
Unit
Factory
Setting
Modi-
cation
Type
F0.15
The function
of lower limit
frequency
0 : R u n n i n g a t l o w e r l i m i t
frequency
1: Stop frequency point
2: Sleep frequency point
0
F0.16
Carrier
frequency
1.0~15.0kHz 1kHz
Different
according
to the
inverter
type
F0.17
PWM mode
selection
0:PWM mode 1
1:PWM mode 2
2:PWM mode 3
0
F0.18
Acceleration
time 1
0.1~3600.0s 0.1s
Different
according
to the
inverter
type
F0.19
Deceleration
time 1
0.1~3600.0s 0.1s
Different
according
to the
inverter
type s
F0.20 Default setting
0:No operation
1: Restore to factory setting
2:Fault record clearing
0
F0.21
Parameter lock
setting
0: Unlock parameter
1: Lock parameter
0
F0.22
Acceleration/
deceleration
method
0: Linear method
1: Reserved
0
F0.23 Reserved
F0.24 Reserved

Table of Contents