● Code :
A3-3111
A3-3112
A3-3113
A3-3114
● Error message :
● Symptom / Cause :
Thermistor sensor is shorted or opened. ADC value is
● Troubleshooting method :
Replace the fuser unit.
CAUTION
The temperature gets high in the vicinity of the fuser
Before replacing it, make sure that fuser unit has co
- 1407-001453 (THERMISTOR-NTC ASSY)
- JC91-00931A (FUSER : 220V)
- JC91-00930A (FUSER : 110V)
Service Manual
CLX-9250/9350 series
7-
ure #A3-3111: Turn off then on.
ure #A3-3112: Turn off then on.
ure #A3-3113: Turn off then on.
ure #A3-3114: Turn off then on.
under 10 or over 4000.
unit. When replacing it, you may get burned.
e.
2. Remove 2 fuser locking screws.
3. Remove the Fuser unit by holding the
handles [A].