● Code :
A3-3411
A3-3412
● Error message :
ctuator Sensor Fai
● Symptom / Cause :
The humidity sensor is short or open.
The output of the outer temperature sensor is more th
● Troubleshooting method :
1. Turn the machine off and on.
2. Enter the Service Mode. (refer to chapter 4. Servic
Check the output of the humidity temperature sens
(Diagnostics > Engine Diagnostics > Engine Test
3. Check the engine board.
● Replacement part
- JC92-02129A : PBA-ENGINE (CLX-9350ND)
- JC92-02239A : PBA-ENGINE (CLX-9250ND)
Service Manual
CLX-9250/9350 series
7-
hooting
lure #A3-3411: Turn off then on.
lure #A3-3412: Turn off then on.
an max. or less than min.
outines > 123-0050 / 123-0070)
SAMSUNG ELECTRONICS