● Code :
C1-2411
C1-3411
C1-4411
C1-5411
● Error message
Magenta toner cartr
Cyan toner cartridg
● Symptom / Cause :
The data of CRUM is not detected.
1. Toner cartridge is not placed in the set.
2. Physical obstacle is jamming the electronic signal t
3. The signal from set is not proper.
● Troubleshooting method :
1. Open the front cover.
Remove the waste toner container.
Open the inside cover.
2 Is the toner cartridge placed in the set or not?
YES! NO! → Place the toner cartridge in the set
↓
Pull out the imaging unit and check the modular j
Is there any contaminations or obstacles?
YES! NO! → Is the modular jack fixed in proper
↓ YES! NO! → Replace the toner car
↓ ↓
↓ Check whether the electronic signal i
↓
Sweep the contaminations or remove the obstacle
Install the toner cartridge and do the reverse of No
Is there the error message?
.
↓
Check whether the electronic signal is proper or n
● Replacement part
- JC92-02129A : PBA-ENGINE (CLX-9350ND)
- JC92-02239A : PBA-ENGINE (CLX-9250ND)
- JC92-02292A : PBA-TONER CONNECTOR
- JC92-02164A : PBA TONER CRUM JOINT
- JC41-00543A : PCB TONER CONNECTOR
Service Manual
CLX-9250/9350 series
7-
e is not installed. Install it.
idge is not installed. Install it.
is not installed. Install it.
is not installed. Install it.
t. Check the connector and engine board.
SAMSUNG ELECTRONICS