● Code :
C3-2211
C3-3211
C3-4211
C3-5211
● Error message
Yellow Imaging unit
Magenta Imaging u
● Symptom / Cause :
Sensor calibration error that detects the toner density
- CTD sensor is contaminated by toner.
- TRC pattern generation error has occurred.
● Troubleshooting method :
1. Select “Auto Color Tone Adjustment” in control pan
(Machine Setup -> General Setting -> Color -> Aut
Select “Menu” and then select “Normal” or “RTC”
2 Print the TRC report (Machine Setup
Check the Pass count and Fail count in TRC report
Check if the Fail count is 0 and LocR, LocC, LocR
If these values are not 0, it means TRC error is occ
3. Check if values of the LedF, LedR, LedC on TRC r
If the value is in this scope, it is normal. If or not, th
So, take off the ITB unit and clean the window of th
Re-install the ITB unit and turn the machine off and
Execute the image density control.
If values of the LedF, LedR, LedC are 1675, CTD s
4. Print the TRC Test Report. Check if the TRC gene
If error has occurred replace the imaging unit
.
5. Print the supply information report, check if the tem
Note : In case that TRC generation error has occurre
- DMA on Magnet roll is low. (Toner is not sup
- Image process is abnormal because of swee
- T1 transfer is defective. So image can’t be fo
● Replacement part
- JC95-01038A : COVER-SIDE TRANSFER ROLLE
Service Manual
CLX-9250/9350 series
7-
error: #C3-2211. Turn off then on.
it error: #C3-3211. Turn off then on.
rror: #C3-4211. Turn off then on.
rror: #C3-5211. Turn off then on.
for image stabilization control has occurred.
el.
port are in 400~800 scope.
image density sensor is contaminated.
ITB unit with soft cloth.
turn it on again.
nsor shutter has any problem. Replace the T2 unit.
ation error is occurred.
porary hard stop has occurred.
lied from toner cartridge.)