● Code :
U1-2132
U1-2135
● Error message :
Fuser Unit Failure #
Fuser Unit Failure #
● S
▶ U1-2132(Center), U1-2135 (Side)
1. FSA error
2. At warm up, the fuser temperature has not reached
● Troubleshooting method :
1. Turn the machine off and turn it on again.
2. Check the following :
. Check the power voltage of the fuser unit. (110V,
B. Check if the Heat lamp is broken.
C Check if the AC connection of Heat lamp is discon
D. Check if the drawer latches have been correctly p
E. Check if the thermostat is blown
F. Check if there is any jammed paper in fuser unit.
G. Check if the resistance value of NC sensor is nor
H. Check if the power voltage is normal. (Is the volta
voltage?)
3. If the problem persists, replace the fuser unit.
4. If the problem persists after replacing the fuser unit
board or SMPS.
● Replacement part
- JC91-00931A : FUSER (220V)
- JC91-00930A : FUSER (110V)
- JC92-02129A : PBA-ENGINE (CLX-9350ND)
- JC92-02239A : PBA-ENGINE (CLX-9250ND)
Service Manual
CLX-9250/9350 series
7-1
hooting
U1-2132 : Turn off then on
U1-2135 : Turn off then on
its normal temperature within the regular time.
e during the operation ±10% of the rated
replace the engine board or fuser control
SAMSUNG ELECTRONICS
30