Installation
24
INSTALLATION
5 INSTALLATION
REQUIRED PPE
5.1 ENVIRONMENTAL
CONDITIONS
The choice of the installation site must
take into account that the machine:
- is not suitable for outdoor installation;
- cannot be installed in areas where the
temperature may fall below 5°C (risk
of water freezing);
- cannot be installed near heat sources
or where the temperature is above
32°C;
- cannot be installed in areas where it
may be exposed to water jets.
≥+5°C ≤+32°C
5.2 INSTALLATION SITE
PREREQUISITES
The
Customer is responsible for
:
- preparation of the support table;
- electrical preparation;
- water preparation.
5.2.1 SUPPORT TABLE
The support table must have the following
characteristics:
- be able to withstand the weight of the
machine in working conditions (with
the water tank full);
- have minimum dimensions equal to the
overall dimensions of the machine;
Risk of failure, falling and cru-
shing the operator.
- be perfectly level, it is forbidden
to install the machine on inclined
surfaces;
Risk, depending on the slo-
pe, that the machine slips or,
more simply, dispenses coffee
unevenly between cups when
dispensing two coffees.