D8
Technical user menu
44
8.3 BOILER TEMPERATURE SETTING
The boiler temperature is set to 123°C
by default.
To set the boiler temperature, proceed as
follows:
- enter the technical user menu, see “8
Technical menu” page 42;
- press the button K1.
The mini-display shows the indication
“tb”.
The boiler can be set as shown in the
table:
But-
tons
Set temperature
K1 120°C
K3 123°C
K4 126°C
To confirm, press the button K5, the sy-
stem returns to the waiting phase for se-
lection.
To set the temperature scale, proceed as
follows:
- press the button K7 to change the
unit of measurement of degrees from
Celsius to Fahrenheit;
The LED L7 is off.
The mini-display shows the indication
“°C”.
- Press the button K7 again to switch to
Fahrenheit.
The LED L7 is on.
The mini-display shows the indication
“°F”.
The LED on indicates the set temperature.
The mini-display shows the set temperatu-
re (e.g. C1-23 / F2-53) as scrolling text.