D8
Installation
29
5.5.2 ELECTRICAL CONNECTION
ELECTRICAL HAZARD
Check that all switches are
in “0” OFF position before
electrically connecting the
machine.
Earthing connection is
absolutely compulsory and the
system must meet the current
regulations in the country of
use.
The power supply line of the machine
must:
- be equipped with an omnipolar
automatic disconnecting switch in
accordance with the disconnection
specifications in overvoltage category
III;
- be dimensioned so that the supply
voltage drop during operation at full
power is less than 2% of the voltage
indicated on the machine’s nameplate.
The machine is factory-set to be wired
directly to the power mains.
To connect the machine to the power
mains:
- check that the machine switch is in the
position “0”;
- switch off the power supply line;
OFF
ON
- check that the mains voltage provided
in the room matches the corresponding
value on the machine’s nameplate;