8.5 PRE-INFUSION SETTING
The machine is delivered with the pre-in-
fusion function disabled.
The pre-infusion can be enabled for sin-
gle, double or both dispensing opera-
tions.
To set pre-infusion, proceed as follows:
- enter the technical user menu, see “8
Technical menu” page 42;
- press the button K3.
The mini-display shows the indication
“PI”.
With all LEDs off, the pre-infusion is di-
sabled.
The mini-display shows the indication
“OF”.
With LED L1 on, pre-infusion is enabled
for single doses.
The mini-display shows the indication
“S_”.
With LED L3 on, pre-infusion is enabled
for double doses.
The mini-display shows the indication
“_d”.
With LEDs L1 and L3 on, pre-infusion is
enabled for all doses.
The mini-display shows the indication
“Sd”.
- Press the button K5 to confirm. The