Electrical Adjustment
Grp / No. Item Function Range Initial Note
9 SHAD_R_DAT2 0 - 255 31
10 SHAD_R_DAT3 0 - 255 31
11 SHAD_G_DAT1 0 - 255 19
12 SHAD_G_DAT2 0 - 255 31
13 SHAD_G_DAT3 0 - 255 31
14 SHAD_B_DAT1 0 - 255 19
15 SHAD_B_DAT2 0 - 255 31
16 SHAD_B_DAT3 0 - 255 31
108 CXD3550_SYC
0 SYC_MASKON 0 - 15 0
1 SYC_VSMAX 0 - 8191 1480
109 CXD3550_FMD
0 FMD_VTFREETH2 0 - 8191 1470
1 FMD_TLOCKTH2 0 - 8191 1465
110 CXD3540_CSC
0 CSC_XH 0 - 1 0
1 CSC_ON 0 - 1 1
2 CSC_R_GP1 0 - 511 324
3 CSC_R_GP2 0 - 511 305
4 CSC_R_GP3 0 - 511 282
5 CSC_R_GP4 0 - 511 259
6 CSC_R_GP5 0 - 511 219
7 CSC_R_GP6 0 - 511 198
8 CSC_R_GP7 0 - 511 172
9 CSC_R_GP8 0 - 511 141
10 CSC_G_GP1 0 - 511 331
11 CSC_G_GP2 0 - 511 309
12 CSC_G_GP3 0 - 511 287
13 CSC_G_GP4 0 - 511 265
14 CSC_G_GP5 0 - 511 231
15 CSC_G_GP6 0 - 511 213
16 CSC_G_GP7 0 - 511 193
17 CSC_G_GP8 0 - 511 166
18 CSC_B_GP1 0 - 511 346
19 CSC_B_GP2 0 - 511 316
20 CSC_B_GP3 0 - 511 290
21 CSC_B_GP4 0 - 511 268
22 CSC_B_GP5 0 - 511 231
23 CSC_B_GP6 0 - 511 209
24 CSC_B_GP7 0 - 511 184
25 CSC_B_GP8 0 - 511 161
200 Option
0 Logo Display Prohibition 0:Menu 1:Forced 0 - 1 0
1 RS232C Baudrate 0: 19200bps 1: 9600bps 0 - 1 0
4 CABLE SW Long Cable 0: Disable 1: Enable 0 - 1 0
5 PW Debug Command Enable
0: Disable (Sanyo Serial Command Enable)
1: Enable (PW Debug Mode)
0 - 1 0
6 Device Refresh Disable 0: Enable 1: Disable 0 - 1 0
8 PJ-NET Hung up check 0: Enable 1: Disable 0 - 1 0
11 HDCP EDID Setting
0: Pattern1
1: Pattern2
2: Pattern3
3: Pattern4
4: Pattern5
0 - 4 0
15 LENS SHIFT SETTING Memorize Lens Position as Center when the value is set to 10. 0 -10 0
21 Lamp Warning Time (NORMAL) 1-16 4
22 Lamp Warning Time (ECO) 1-16 6
23 Lamp Warning Time (HIGH) not supported 1-16
50 Lamp Replacement Display 1:On 0:Off 0 - 1 1
51 Filter Warning Display 1:On 0:Off 0 - 1 1
52 Lamp Counter Reset Times mot supported 0 - 255 0
53 Filter Counter Reset Times Read only 0 - 255 0
54 Factory Default Execute Times Read only 0 - 255 0
55 Motor Operation Stop 0: Enable 1: Disable 0 - 1 0
58 Lamp Go Out Lamp goes out 0 - 1 0
63 Source Search Enable 0: Disable 1: Enable 0 - 1 1
64 Input Search Skip Enble 0: Disable 1: Enable 0 - 1 1