-56-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
70 ADC Device Select for Analog PC 0 = ISL51002, 1 = PW392 AFE 0 - 1 0
71 ADC Device Select for Component 0 = ISL51002, 1 = PW392 AFE 0 - 1 0
72 Component/RGB Auto SW 0: Disable 1: Enable 0 - 1 1
80 Destination Language Set at Shipping 0:English :Japanese 0 - 1 0
95 Flicker 1 0: Disable 1: Enable 0 - 1 0
96 Flicker 2 0 - 15 8
100 Disable Auto Picture Control 0 : Normal operation 1 : Auto Picture Control Off 0 - 1 Initial: 1 Shipping 0
110 Monitor Output during Cooling 0: On 1: Off 0 - 1 0
112 Monitor Out Link with Video Mute 0: Not link 1: Link 0 - 1 1
120 HDMI Cont at Standby 0: Not control 1: Allow to control 0 - 1 1
130 Logo Countdown time 0: 30 sec. 1: 20 sec. 0 - 1 0
140 Offset Add Status 0: Not use Offset addition - 0 Read only
141 Offset Change Apply offset value when the value is set to 10. 0 - 10 0
142 Offset Value Offset value at Shutdown temp. - 10 Read only
143 Executed times of Offset Add - 0 Read only
144 Canceled time of Offset Add - 0 Read only
170 Power Mgmt Shutdown time unit: hour 1 - 24 3
180 CcaTargetLinkedChange "YCM" lenked function on Color matching Target change 0 - 1 1
201 Option (Signal)
0 FrameLock Option
0: Off for PC signals
1: Off for AV signals
3: Normal
4: Normal
0 - 4 4
1 Dither Enable 0: Disable 1: Enable 0 - 1 0
3 Field Sens Invert Enable 0: Disable 1: Enable 0 - 1 0
205 Spread Spectrum
0 Enable 0: On 1: Off 0 - 1 1
1 Ratio 0 to 300 0 - 300 200
2 Frequency 200 to 500 1 - 500 350
210 Lamp Contorl
0 Dimmer SW 0:Auto 1:Manual 0 - 1 0
1 Manual Control
Lamp Power Manual Control (DIMMER_CTRL_LEVEL
0(Dark)~15(Bright))
0 - 15 0
19 DIMMER_LEVEL_AUTO Current Y Level (Read only) - - Read only
20 DIMMER_LEVEL_NORMAL Dim Level at Normal 0 - 15 15
21 DIMMER_LEVEL_ECO Dim Level at Eco 0 - 15 0
23 VOLTAGE_LEVEL Lamp Voltage (Read only) - - Read only
220 Projector Error Log
0 Warning_Log_1 Latest Error log 0 - 32767 0
: : : : :
49 Warning_Log_50 50th Error log 0 - 32767 0
50 Warning_Log Reset Log is cleared when the value is set to 10. 0 - 10 0
235 Shutter
0 PRE_MOTION Shutter Warm - up Operation (0: Yes, 1: No) 0 - 1 Initial: 1 / Shipping: 0
1 CMP_TRM Chattering Detecting Term 0 - 32767 7000
2 OUT_DLY_TRM Output Term 0 - 32767 15000
3 CMP_CHK_CNT Count of Information Sync 0 - 15 0
4 OPEN_DLY Open Output Delay 0 - 63 0
5 CLOSE_DLY Close Output Delay 0 - 63 0
6 Position Check Time Position Check Time 1 - 255 50
8 Enable Close Cmd Shutter Close Command 0: Disable 1: Enable 0 - 1 1
9 Speed Control Shutter Speed 0 - 255 0
10 Shutter Management Upper Time Shutter Manement Time for Upper limit 180 -999 480
240 Flow Calibration
0 Flow Calibration Exe
Flow Sensor Offset Calibration Start calibration when the value
is set to 1.
0 - 1 0
* Wind sensor calibra
-
tion.
1 Flow Calibration Error Log
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
- 255
2 Clog Check Enable Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable) 0 - 1 Initial: 0 / Shipping: 1
4 Time Limit Auto Scroll Enable Auto Scroll for Manimum Time (o: Disable 1: Enable)) 0 - 1 1