-59-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
4 Press Sensor Log
0: Calibration executed correctly
10: Out of Range Offset Min.
20: Out of Range Offset Max.
99: Calibration not excuted
- 99
250 Fan Voltage Adjustment
0 Fan 1 Min Adjust (DAC)
DAC Output for Fan Voltage adj.
Adjust Tolerance between DAC and Fan Volt.
*Lamp Mode: Eco
0-255 20 * Fan voltage adj.
1 Fan 1 Max Adjust (DAC) 0-255 240 * Fan voltage adj.
2 Fan 2 Min Adjust (DAC) 0-255 20 * Fan voltage adj.
3 Fan 2 Max Adjust (DAC) 0-255 235 * Fan voltage adj.
4 Fan 3 Min Adjust (DAC) 0-255 20 * Fan voltage adj.
5 Fan 3 Max Adjust (DAC) 0-255 240 * Fan voltage adj.
6 Fan 4 Min Adjust (DAC) 0-255 15 * Fan voltage adj.
7 Fan 4 Max Adjust (DAC) 0-255 230 * Fan voltage adj.
8 Fan 5 Min Adjust (DAC) 0-255 15 * Fan voltage adj.
9 Fan 5 Max Adjust (DAC) 0-255 215 * Fan voltage adj.
10 Fan 6 Min Adjust (DAC) 0-255 15 * Fan voltage adj.
11 Fan 6 Max Adjust (DAC) 0-255 215 * Fan voltage adj.
12 Fan 7 Min Adjust (DAC) 0-255 15 * Fan voltage adj.
13 Fan 7 Max Adjust (DAC) 0-255 240 * Fan voltage adj.
252 Fan Option
1 Safety Switch Safety Application use 0-6 0
2 Fan Manual Switch Fan Manual SW (0: Auto 1: Manual) 0-1 0
3 Fan1 Manual Voltage
Manual Adjustment Mode (0.1V)
*Effective only when Manual SW is 1.
0-255 100
4 Fan2 Manual Voltage 0-255 100
5 Fan3,4 Manual Voltage 0-255 100
6 Fan5 Manual Voltage 0-255 100
7 Fan6 Manual Voltage 0-255 100
8 Fan7 Manual Voltage 0-255 100
9 Fan8 Manual Voltage 0-255 100
10 Angle Data A Angle Data A (Read only) - -
11 Angle Data B Angle Data B (Read only) - -
12 Press Data Air Pressure Data (Read only) - -
253 Fan Temp Error Setting (Memorized) Normal Ceiling Top Bottom
5 Temp A Warning (Normal) Temp A (Room) to judge the Temp Error at Normal 30-100 47 47 47 47
6 Temp B Warning (Normal) Temp B (Lamp) to judge the Temp Error at Normal 30-100 80 80 80 80
7 Temp C Warning (Normal) Temp C (Panel) to judge the Temp Error at Normal 30-100 68 68 68 68
8 Temp B-A Warning (Normal) Temp B - A (Filter Clogged) to judge the Temp Error at Normal 0-100 50 50 50 50
9 Temp C-A Warning (Normal) Temp C - A (Filter Clogged) to judge the Temp Error at Normal 0-100 32 32 32 32
10 Temp A Warning (Eco) Temp A (Room) to judge the Temp Error at Eco 30-100 47 47 47 47
11 Temp B Warning (Eco) Temp B (Lamp) to judge the Temp Error at Eco 30-100 80 80 80 80
12 Temp C Warning (Eco) Temp C (Panel) to judge the Temp Error at Eco 30-100 68 68 68 68
13 Temp B-A Warning (Eco) Temp B - A (Filter Clogged) to judge the Temp Error at Eco 0-100 50 50 50 50
14 Temp C-A Warning (Eco) Temp C - A (Filter Clogged) to judge the Temp Error at Eco 0-100 32 32 32 32
15 Temp A Warning Offset (Temp)
Temp Warning Offset (Temp)
0-100 13
16 Temp B Warning Offset (Temp) 0-100 13
17 Temp C Warning Offset (Temp) 0-100 13
18 Temp B-A Warning Offset (Temp) 0-100 13
19 Temp C-A Warning Offset (Temp) 0-100 13
20 Temp A Warning Offset (Time)
Time Warning Offset (Time)
0-40 3
21 Temp B Warning Offset (Time) 0-40 3
22 Temp C Warning Offset (Time) 0-40 3
23 Temp B-A Warning Offset (Time) 0-40 3
24 Temp C-A Warning Offset (Time) 0-40 3
Top
30°
330°
150°
210°
Bottom
Ceiling
Normal
254 Fan Control Range Setting (Temp/Spinning) Normal Ceiling Top Bottom
16 Normal Fan Control Min Temp
Temp Sensor Control Start/End Temp St Normal
20-100 31 31 31 31
17 Normal Fan Control Max Temp 20-100 38 38 38 38