INTEGRA SATEL
13
user has access to a single partition only, entering the code and pressing [#] results in
immediate arming or disarming (if the partition is armed).
Entering the code and pressing [
*
] displays the list of functions accessible from the User
Menu. The User Menu provides also access to the following functions: Arming and Disarming
(if some partitions are armed). When all partitions are armed, the function Arming will not be
accessible.
Note: Entering a wrong code (not recognized by the panel) three times may:
− trigger an alarm PROG,
− block a keypad for 90 sec. After this time each next wrong code entering will block
the keypad PROG.
The specific feature of the control panel is the dynamic changing of the accessible menu,
dependant on the system programmed parameters, as well as on the authorization level of
the user who entered the code. The user get access only to those function in the user menu
to which he is authorized.
In order to call some functions more quickly, the user can use some SHORTCUT KEYS.
Having called the menu ([CODE][
*
]), press the suitable numerical key – the control panel will
enter directly the called function.
The following user functions are assigned to the corresponding keys:
[1] Change own code
[2] Users/Masters
[3] none
[4] Zone bypasses
[5] Events
[6] Set time
[7] Troubles
[8] Outputs control
[9] Service mode
[0] Downloading
The installer can assign functions to the arrow keys to facilitate the everyday operation of
the system. These functions are called in the following way:
[CODE] S
[CODE] W
[CODE] X
[CODE] T
One of the following functions can be assigned to each arrow:
− Arming (full)
− Arming (without interior zones)
− Arming (without interior zones, without entry delay)
− Disarming
− Alarm clearing
− Zones bypassing
− Bypass clearing
− Output MONO ON
− Output BI switch state
− Output BI ON
− Output BI OFF