User Manual INTEGRA
40
7.2 D
ESCRIPTION OF USER FUNCTIONS
View cleared alarms
The function is available, provided that the user has not viewed the violated zones. It makes
it possible to check which zones triggered the alarm. After completion of the viewing, the
function will be unavailable.
System reset
The function is available to the installer (service), if the option R
EQUIRED
S
YSTEM
R
ESET AFTER
VERIFIED ALARM
is enabled, and a verified alarm took place. After occurrence of the verified
alarm, it is necessary to reset the system by means of this function, in order to make re-
arming possible.
Disarm
The function allows disarming of one or several selected partitions, or all partitions accessible
to the user, from the given keypad.
Clear alarm
The function clears alarm signaling on outputs, in partition keypads, in code locks and
proximity cards/DALLAS chip readers.
Clear other alarms
The function makes it possible to cancel alarms from other objects, to which the user has
normally no access.
Abort voice messaging
When this function is called, the telephone messaging is stopped – the control panel should
ring off. If the telephone line is still occupied, there must be messaging in the process from a
partition non-accessible to the given user.
The messaging by telephone may be cancelled automatically together with an alarm clearing
PROG.
Note: If the installer fails to assign the selected telephone number to a partition the users of
which are authorized to cancel the voice messaging, the procedure of voice
messaging will run to the end, without any possibility to stop it.
Arm
The function allows arming of one or several selected partitions, or all partitions accessible to
the user.
Arm (2 codes)
The function arms special partitions, where two different codes must be used for arming. The
presence of such partitions is declared (programmed) by the installer.
Entering the first code on the LCD keypad will display a list of partitions from which you
should select those to be armed. After acknowledgement of the selected partitions, the
control panel enables programming of the code validity time – you should indicate the time
period within which the second code can be entered (maximum 18 hours, 12 min.); by
default, this time is set at 1 minute.
During the first code validity time, the partitions available for arming are indicated on the LCD
keypad by slow blinking of the partition status indicator (2s/2s), and on the partition keypad -
by rapid, alternate blinking of the [
ARMED
]
and [
TROUBLES
]. LEDs. During that time the
control panel makes available the selected partitions for arming to the users who may enter