Set auto-arming delay
The function puts off (delays) arming of a timer-controlled partition (auto-arming). It is used
for programming the value of time interval by which the moment of automatic arming of a
partition is to be delayed. The maximum delay time is 4 hours, 33 minutes and 3 seconds.
Entering a higher value will set the maximum permissible value, while entering the zeros
alone will restore the partition control according to the installer’s settings. Operation of this
function pertains both to the partition timers programmed by the user, as well as to the those
programmed by the installer.
The delay time is programmed individually for each automatically controlled partition.
The function is available in the user menu if the user is authorized to get access to at least
one partition for which a non-zero "auto-arming delay" time has been set PROG. The
value of such a delay may vary from 1 to 255 seconds.
Activation of the timer controlling the particular partition starts the process of counting the
auto-arming delay time. Then, countdown of the partition exit delay takes place (if any),
followed by arming of the partition.
Arming mode
This function makes it possible to select a special mode of arming and is called when the
user wants to remain in the facility. There are three options of arming modes:
• Full (default)
• Stay
• Stay, delay = 0 (off)
Details regarding the use of functions are discussed in section "System Armed Mode", page
24.
After selection of the armed mode, the control panel returns to the user function menu, thus
enabling the selected partitions to be armed.
Exiting the menu without arming ([
*
] key) will cancel the selection made with this function.
Cancel 1st code
This function makes it possible to cancel the decision to enter the first code for
arming/disarming the two-code operated partitions. After calling the function, the control
panel will display the list of partitions for which the given user has entered the first code, and
will start countdown of the code validity time. You should select the required partitions from
the list and press [#]. Validity of the first code for arming/disarming the selected partitions will
be cancelled.
Change own code
This function makes it possible to change the code of the user, who called this function. For a
better safety of the system, it is recommended to change user code periodically (there is
always a risk that an unauthorized person might have seen the code).
The control panel requests the user to change his code in the following cases:
• New user – the new user code is known to the person who has entered him in the system,
therefore it must be changed. Until the code is changed by the new user, the "Change
code" message will be displayed. A failure to comply with this request has no
consequences in terms of the assigned authority level and/or access to the partitions.
• Expiry of the validity time of the "Time renewable" code (see the U
SERS
function).
• Hitting the user code – it may happen when entering a new code by any user that he
enters a code already used in the system. Such a "guessed" code will be rejected,
however its present user will be informed that it is necessary to change the code.