User Manual INTEGRA
52
been programmed. The function makes it possible to manually initiate synchronization of
the control panel clock with the time server.
Note: If the time synchronization is going on (initiated automatically or manually), the
function is unavailable.
No additional message is displayed at the time of exiting the function.
Service access
The function allows the installer to access the system by means of the service code. It is only
accessible in the master user menu. It requires some data to be entered i.e. the number of
hours during which the alarm system will be available to the installer (service). After that time
the access to the system will be blocked.
Entering “zero" with this function (in place of number of hours), when the system is open to
the service, will automatically block the access.
The access time countdown is running whether the service mode is started or not, and can
only be interrupted by disconnecting power supply (230V mains and battery). By calling this
function you can check how much time is left (out of the access time limit granted by the
master user) – "00" indicates that the last hour is expiring.
Open door
By using this function it is possible to open any door controlled by the alarm system (C
ARD
READ
EXPANDER
type outputs, partition keypads, code locks and proximity card/DALLAS
chip reader expanders).
Outputs control
The function is available to the users with assigned C
ONTROL
right. It allows the user to
enable/disable single outputs, type MONO
SWITCH
, BI
SWITCH
, R
EMOTE SWITCH
,
S
HUTTER UP
and S
HUTTER DOWN
, and, thereby, to operate particular devices. In order to make the output
available for control, it must be assigned by the installer to one of the 4 output groups. An
individual name can be assigned to each group.
Starting the function by the user will display a list of output groups. You can scroll the by
means of the S and T keys. After selecting one of the output groups and pressing the [#] or
X key, a list of controllable outputs will be displayed. Press the W key to return to the group
list.
Note: If the outputs are only assigned to one output group, starting the O
UTPUTS CONTROL
function will not be followed by displaying the list of output groups in the keypad, but
immediately by the list of controllable outputs.
To quit the function, press the [
*
] key.
Controlling the MONO
SWITCH
and BI
SWITCH
type of outputs
The output status is indicated on the display as follows:
output inactive (off),
O output active (on).
The output is controlled by means of the [#] or X key. Pressing the key will activate the
MONO
SWITCH
for a preprogrammed period of time or toggle the status of the BI
SWITCH
type
of outputs.
Output activation is signaled by four short and one long beeps. Toggling the BI
SWITCH
to its
inactive state is signaled by three short beeps.