INTEGRA SATEL
31
not violated during this time, the control panel will display a list of faulty zones (number and
name of zone) and will not arm the system.
Pressing the digit 1 key during the process of countdown will interrupt the test and arm the
system in normal mode, while pressing the [
*
] key will make it possible to cancel the arming.
Arming the system from the partition keypad will bypass the testing of vibration sensors in the
particular partition.
The user can disarm the system using one of the following ways:
entering [CODE][#] in LCD keypad – all partitions or some selected partitions only can
be disarmed;
entering [CODE][
*
] or [CODE][#] in partition keypad – the partition to which the keypad
is assigned can be disarmed;
entering [CODE][
*
] in LCD keypad and choosing "Disarm" function – selected
partitions can be disarmed;
bringing closer or holding card in the proximity of the reader (depending on
expander settings) the partition to which the reader is assigned will be disarmed;
bringing closer or holding DALLAS chip in the reader (depending on expander
settings) – the partition to which the reader is assigned will be disarmed.
Also, special control ways of partition status are possible:
partition arming and disarming by means of timers. The timer is an internal control panel
logic unit which measures time. Timer operation is programmed by the service;
partition arming and disarming by the “partition user timer". Operation of this timer may be
programmed by the partition user, without having the installer (or the service) to do the job.
There is a single partition timer of this type, which can be programmed in daily or weekly
cycle (see: Description of user functions
Æ
C
HANGE OPTIONS
);
Note: The special armed modes, as described earlier, are also defined for timers.
partition arming control by means of a special zone programmed (by the installer) as
arming control zone. In practice, it may be a mechanical switch; key switch, pushbutton,
radio switch. It is also possible to control such a zone by means of the R
EMOTE SWITCH
type output (see: Answering phone call). Disarming by means of the zone can also clear
the alarm and telephone messaging;
Note: The zone will arm always, unless the option C
HECK ARM POSSIBILITY
is enabled. If this is
the case, all the conditions which make arming impossible (see page 29) will be taken
into consideration.
arming/disarming by the use of code and arrow keys (see: Use of LCD keypad) – this
mode facilitates access to the above mentioned "special ways of arming".
6.12 A
LARMS
The system may signal alarms as the response to various situations that occurred in the
protected facility. The basic control panel alarms include:
Burglary alarm – activated when the zone is violated in the partition where arming is on.
Violation of the “delayed zone" starts countdown of the delay time, after expiry of which
an alarm is activated unless the partition is disarmed.
Fire alarm – activated by fire detectors, from keypad or otherwise (e.g., by pressing
pushbutton).
Tamper alarm – activated by violation of any tamper contacts in the alarm system (located in
detector and module casings), damage to cables, etc.