Change options
This function controls the “CHIME" type signaling and allows setting the partition user
timer which automatically arms and disarms the partition, sets the mode of service code
access to the system, and deletes the service message.
Keypad chime – signals the violation of any zone (detector) selected by the installer. Some
zones may be selected which will activate signaling in the keypad. The chime signal in
each keypad may be activated from different zones. The function makes it possible to
disable and enable this signaling in the keypad from which it was called.
Outputs chime – the function makes it possible to block the signaling of zone violations from
selected partitions on the C
HIME
type output, provided that the installer permits blocking for
those partitions.
Partition timers (see section System Armed Mode) allow automatic zone arming and
disarming.
For the timer to operate it is necessary to:
1. Start the A
CTIVE
function and enable it ( ).
2. Select operation mode: everyday or weekly.
3. Set the timer on and/or off time.
In case of the daily cycle timer, after selecting the mode, the "Every day timer turned
on: HH:MM" text will appear on the display. Enter the hour (HH) and minute (MM) of
switching the timer on. Press S or T to enter hour and minutes of switching the
timer off.
For the weekly cycle timer, the time of switching on and/or off is programmed in the
same way, but it should be done for each weekday separately.
Note: Entering the nines only will deactivate the given function (arming or
disarming).
Example: The timer may arm only at a specified time, but disarming must be done by
the user himself; automatic partition control may be activated on some
weekdays only.
4. Determine the armed mode which should be enabled by timer: 1 – fully armed, 2 –
armed without interior, 3 – armed without delayed. By default, the control panel
assumes that each new timer enables the fully armed mode (type 1).
5. Confirm the entered data by pressing [#]. The name of the timer set will be displayed,
together with preprogrammed data.
6. Save the timer settings in the control panel memory. For this purpose, press the [
*
] key
and accept the changes with the key [1].
No expanders tamper alarms – should any problems occur in communication with the
expansion modules, report it to the service. The function allows to temporarily disable the
expander tamper control.
Permanent service access – selecting this option will make unnecessary entering the
service access time by the master user – the service code will be always accepted by the
control panel. This function is accessible to the master user only.
Note: Setting any "access time" by means of the S
ERVICE ACCESS
user function will disable
the option, while selecting the option will reset time limitations entered by this
function.
Clear service message – it is possible to delete the service message (see LCD keypad),
which is displayed by the installer using a suitable service function. The installer can define
the user(s) authorized to deactivate the display of technical information, such a user
getting access to the option described herein.