The user who wants to run any function from the entry keypad must be authorized to use it
(the right is granted by the administrator or installer (service)). Except for the guard round
confirmation function, he must also have access to the given partition. Realized by the
keypad after entering the access code / presenting the card, the function depends on the
user authority level, keypad settings and security system status.
Note: Entering an invalid access code (i.e. unknown to the control panel) or placing an
unknown card in proximity may:
− trigger the alarm PROG;
− block the keypad for 90 seconds. After the blocking time has expired, entering
another invalid access code / reading in an unknown card will each time block the
keypad PROG.
In the entry keypad, only the LED designated is used for signaling. Blinking of the LED
indicates that countdown of the delay activation time is running (disarming has no effect on
the LED blinking).
The entry keypad can generate the following audible signals:
• One short beep – confirmation of access code entry or card read-in (the A
CCESS CODE
SIGNALING
(
HARDWARE
)
option
must be enabled by the installer).
• Two long beeps – access code / card unknown to the control panel.
• Three long beeps – activation the delay is impossible (the partition is disarmed or the
delay has already been started) or the function is unavailable.
• Three short beeps – confirmation of delay activation.
• Three pairs of short beeps – the user code needs to be changed (the N
OTIFY OF
NECESSITY TO CHANGE ACCESS CODE
option is enabled in the control panel).
• Four short beeps and one long beep – confirmation of the guard round or execution of
the 24. MONO
S
WITCH
or 25. BI
S
WITCH
control function.
The audible signaling may be replaced by blinking of the keys backlight PROG. The beeps
will translate, respectively, into keypad backlight extinguishments – if the backlight is ON, or
into keypad backlight going on - if it is normally OFF.
The keypad can also audibly signal the D
ELAY ACTIVATION TIME
PROG.
6.6 C
ODE LOCKS
SATEL offers the following code locks for the INTEGRA control panels:
− INT-SZ-GR/INT-SZ-BL
− INT-SZK-GR
They differ by their size and shape. The code locks are available with green or blue
backlighting. Designation of the models with green backlighting ends with "GR" letters, while
that of the models with blue backlighting – with "BL" letters. The backlighting can be either
permanent, or time-controlled (automatically activated).
The code locks are provided with LED indicators:
–
ACTIVE
(green) – lighting of the LED indicates that the lock is operated by the control
panel.
–
ACCESS
(depending on the lock type, of blue or red color) – lighting indicates unlocking
of the door lock, which means that the door may be opened.
–
DOOR
(yellow) – lighting informs that the door is open.