the other code in the same way as for the partitions armed with a single code. The user who
has entered the first code has the option to cancel his "consent" to arming of selected
partitions (see description of the C
ANCEL
1
ST CODE
function).
If the first code was entered from the partition keypad, then the other one must be entered
within 1 minute of entering the first one, as after expiry of that time the control panel returns
to its basic mode. The system may demand that the second code be entered from another
keypad (partition keypad) which operates that partition. The users authorized to enter the first
or second code in such partitions are assigned by the installer.
Disarm (2codes)
The function disarms special partitions where two different codes must be used for disarming.
The presence of such partitions is declared (programmed) by the installer.
Entering the first code on the LCD keypad will display a list of partitions from which you
should select those to be disarmed. After acknowledgement of the selected partitions, the
control panel will request the code validity time – you should indicate within what time the
second code can be entered (maximum 18 hours, 12 min.).
During the first code validity time, the partitions available for disarming are indicated on the
LCD keypad by slow blinking of the partition status indicator (2s/2s), and on the partition
keypad – by rapid, alternate blinking of the [
ARMED
]
and [
TROUBLES
]
LEDs. During that
time the control panel makes available the selected partitions for disarming to the users who
may enter the other code in the same way as for the partitions disarmed with a single code.
The user who has entered the first code has the option to cancel his "consent" to disarming
of selected partitions (see description of the C
ANCEL
1
ST CODE
function).
If the first code was entered on the partition keypad, then the other one must be entered
within 1 minute of entering the first one, as after expiry of that time the control panel returns
to its basic mode. The system may demand that the second code be entered from another
keypad (partition keypad) which operates that partition. The users authorized to enter the first
or second code in such partitions are assigned by the installer.
Defer auto-arming
The function puts off (delays) arming of a timer-controlled partition (auto-arming). It is used
for programming the value of time interval by which the moment of automatic arming of a
partition is to be delayed. The maximum delay time is 4 hours, 33 minutes and 3 seconds.
Entering a higher value will set the maximum permissible value, while entering the zeros
alone will cancel the timer-controlled arming until the particular timer is activated again.
Operation of this function pertains both to the partition timers programmed by the user, as
well as to the those programmed by the installer.
The function makes it possible to select the partitions where the countdown of the
auto-arming delay has begun. Exactly this feature distinguishes the said function from the
described below S
ET AUTO
-
ARMING DELAY
user function which gives access to all the partitions
armed automatically with time delay and available to the individual user. In view of a low
value of the auto-arming time (max. 255 seconds), it is important that a quick option of the
partition arming delay be available in case it is necessary to stay inside.
Upon commencement of the countdown, the control panel can display on the LCD keypad
the partition name and the delay time which remains to arming PROG. If the time is
simultaneously counted in several partitions, the display shows the name of the partition
which will be armed first.
The delay time is programmed individually for each partition for which the auto-arming delay
countdown has begun.