User Manual INTEGRA
22
Functions executed after entering the access code and confirming it with the key or
presenting the card (the function to be executed depends on the user authority level, keypad
settings and security system status):
– relay activation
– disarming
– clearing alarm
– 24. MONO
S
WITCH
output control
– 25. BI
S
WITCH
output control
– guard round confirmation
– enabling temporary partition blocking
Note: Most of the abovementioned functions is available after enabling the L
OCK
option.
Availability of the functions may also depend on other keypad options (e.g. if the lock
executes the ON
IF PARTITION ARMED
function, most of the operations will be
unavailable). None of these limitations refers to the functions executed after entering
the access code and confirming it with the key or holding the card.
Functions executed after entering the access code and confirming it with the key or
holding the card (the function to be executed depends on the user authority level, keypad
settings and security system status):
– arming
– disarming
– clearing alarm
– 24. MONO
S
WITCH
output control
– 25. BI
S
WITCH
output control
– guard round confirmation
– enabling temporary partition blocking
Functions which are available from the keypad without entering any access code:
– press the and
keys in turn – quick partition arming
– hold down the key for about 3 seconds – FIRE alarm
– hold down the key for about 3 seconds – AUX (medical) alarm
– hold down the key for about 3 seconds – PANIC alarm
Another function of the keypad is the option to change the access code by the user PROG.
In order to change the user code, do the following:
1. Press and hold down the key for about 3 seconds (LEDs designated and
[
ALARM
and
ARMED
]
will start blinking alternately – red and green).
2. Enter the old ACCESS CODE and press (LEDs designated and [
ALARM
and
ARMED
]
will start blinking alternately – red and yellow).
3. Enter the new ACCESS CODE and press (the LEDs will stop blinking and the module
will generate a signal to confirm execution of the function).
The control panel may in four cases fail to accept the access code change (which will be
signaled by two long beeps):
1. The new access code is too short or too long (permissible length is from 4 to 8 digits),
2. The new access code is too simple (simple access code checking feature has been
started in the control panel),
3. The new access code is the same as that of another user of the security alarm system
(somebody else's password has been „hit”),