Changes in the INTEGRA control panels with firmware in version 1.05
Support of new
modules
INT-SCR-BL – multifunctional keypad which can work as a partition
keypad (identified as INT-S/SK), partition keypad with reader
(identified as INT-SCR) or entry keypad (identified as INT-ENT)
INT-ORS – DIN-rail outputs expander
INT-IORS – DIN-rail zones/outputs expander
INT-RX – 433 MHz remote key fob operation expander
Timers Defining the armed mode to be activated by timer: fully armed, armed
without interior or armed without delayed.
Users A remote key fob can be assigned to each user.
A zone which will be violated by pressing a button / combination of
buttons can be assigned to each key fob button / two button
combinations (1 & 2 and 1 & 3).
Arming The arming procedure in LCD keypad has been modified. If arming is
impossible (because of zone violation, tamper, trouble, etc.) and the
keypad has displayed a list of causes for such a situation, you can
make another attempt to rearm by pressing the [#] key (without
reentering the access code or selecting the armed mode status and
partitions).
User functions The Z
ONES TEST
function
has been modified by adding the option to
terminate the test before the programmed time has expired.
The T
IME SYNCHRONIZATION
function has been added.