EasyManua.ls Logo

Scanreco G6 - SRDO Data Frame; Examples; Safe State; Safe Standstill State

Scanreco G6
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Scanreco – Service Manual G6 Radio Remote Control System
COB-ID DLC D0 D1 D2 D3 D4 D5 D6
0xFF + (2 *
NODE_ID)
7 STOP NC STOP NO MOVE SANP
9-16
SANP
1-8
SDP
5-8
SDP
1-4
Msg 1
COB-ID DLC D0 D1 D2 D3 D4 D5 D6
0x100 +(2 *
NODE_ID)
7 ~STOP NC ~STOP NC ~MOVE ~SANP
9-16
~SANP
1-8
~SDP
5-8
~SDP
1-4
Msg 2
2.2. Examples
Node ID = 1
COB-ID DLC D0 D1 D2 D3 D4 D5 D6
0x101 7 STOP NC STOP NO MOVE SANP
9-16
SANP
1-8
SDP
5-8
SDP
1-4
0x00 0xFF 0x00 0x00 0x00 0x00 0x00
Msg 1
COB-ID DLC D0 D1 D2 D3 D4 D5 D6
0 x 102 7 ~STOP NC ~STOP NO ~MOVE ~SANP
9-16
~SANP
1-8
~SDP
5-8
~SDP
1-4
0 x FF 0 x 00 0 x FF 0 x FF 0 x FF 0 x FF 0 x FF
Msg 2
2.2.2. Safe Standstill State
COB-ID DLC D0 D1 D2 D3 D4 D5 D6
0 x 101 7 STOP NC STOP NO MOVE SANP
9-16
SANP 1-8 SDP 5-8 SDP 1-4
0 x 00 0 x FF 0 x FF 0 x FF 0 x FF
1
0bhhggee
1
0bddccbbaa
Msg 1
COB-ID DLC D0 D1 D2 D3 D4 D5 D6
0 x 101 7 STOP NC STOP NO MOVE ~SANP
9-16
~SANP
1-8
~SDP 5-8 ~SDP 1-4
0 x 00 0 x FF 0 x FF 0 x FF 0 x FF ~0bhhggee ~0bddccbbaa
Msg 2
2.2.3. Safe State
2.1. SRDO Data Frame
– 3 –

Table of Contents