IO-Link Data Dictionary SCPSi series
21.10.01.00065/02 29.08.2014
J. Schmalz GmbH
Aacher Straße 29, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
info@schmalz.de
Remark
Counter value cc1 of when the entry was recorded
Bytes 12…17 Bytes 223…228 Remark
Entry 3 Entry 38 (oldest) Buffer of 38 entries (newest to oldest) with encoding as in ISDU 131
Remark
Single entry was written incorrectly - do not evaluate
Notification: Manual mode exited
Notification: Corrupted entry
Description
Encoding of Diagnostic-Type
Diagnostic-Type
Bytes 2…5
0x1404 Notification: Vacuum sensor calibrated successfully
Notification: Diagnostic buffer cleared
Notification: Parameters restored to factory defaults
0x1403
0x1405 Notification: Manual mode entered
0x0405
Data Format of Single Entry (ISDU 132)
Diagnostic-Type (MSB first)
Bytes 0…1
Entry 1 (newest) Entry 2
Counter cc1 (MSB first)
Data Format of Diagnostic Buffer (ISDU 131)
Notifications
0x1401
0x1402
Notification: Device powered on
0x14AA
Diagnostic Buffer - Details
Bytes 0…5 Bytes 6…11