IO-Link Data Dictionary SCPSi series
21.10.01.00065/02 29.08.2014
J. Schmalz GmbH
Aacher Straße 29, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
info@schmalz.de
Remains until next power-on
Remains until next power-on
Remains until next suction cycle
Remains until next suction cycle
Remains until next suction cycle
Remains until next suction cycle
Error E17 appeared: Primary voltage US too high
Error E03: Vacuum sensor calibration failed
Error E17 disappeared: Primary voltage US too high
Error E18 appeared: Input pressure outside operating range
Error E18 disappeared: Input pressure outside operating range
0x0208
0x1201 Error E01: Internal Error
0x1211
0x1207
0x1180
0x0180
CM-Warning appeared: Input pressure outside of operating range
CM-Warning disappeared: Input pressure outside of operating range
0x0211
CM-Warning: Valve protection activated
0x1208
0x1203
0x0207
0x1202
Errors
Error E02: Internal Error
Error E07 appeared: Primary voltage US too low
0x1120
0x0120
CM-Warning appeared: Primary voltage US outside of optimal range
CM-Warning disappeared: Primary voltage US outside of optimal range
0x1108
0x0110
CM-Warning: H1 not reached in suction cycle
CM-Warning disappeared: Free-flow vacuum > (H2-h2) but < H1
0x1102
0x1104 CM-Warning: Leakage rate above limit [-L-]
CM-Warning: Evacuation time t1 above limit [t-1]
0x1110 CM-Warning appeared: Free-flow vacuum > (H2-h2) but < H1
0x1212
0x0212
Error E07 disappeared: Primary voltage US too low
Error E08 appeared: IO-Link communication interrupted
Error E08 disappeared: IO-Link communication interrupted
0x120C Error E12 appeared: Short-circuit at OUT2
0x020C Error E12 disappeared: Short-circuit at OUT2
Condition Monitoring Warnings
0x1101
J. Schmalz GmbH
10 of 11 SCPSi Data Dictionary

Table of Contents