11
Technical data
Radio modem
Operating Instructions – MOVIPRO
®
PHC11A-..M1-..2A-A1/..
102
11.6 Radio modem
For more information, technical data and approvals, refer to the latest edition of the
addendum to the "MOVIPRO
®
Drive and Application Controller REC5 Radio Mo-
dem" operating instructions.
11.7 Safety technology
11.7.1 General
Safety characteristics
Approved safety
classes of the unit
Performance level d according to EN ISO 13849-1
Service life 20 years
Safe condition Frequency inverter does not produce a rotating field, power
to the connected brakes is turned off
11.7.2 STO interfaces
Input for safe disconnectionX5502
Control voltage range
according to
DIN EN 61131-2
Min. 20.4 V
Typ. 24.0 V
Max. 28.8 V
Output current limit DC
24 V
Max. 2 A (until thermal switch-off)
The continuous output current must not exceed 500 mA.
Single drive input ca-
pacitance (diode-de-
coupled)
32 µF
20278543/EN – 09/2014