5
Mechanical installation
Assembly
Operating Instructions – MOVIPRO
®
PHC11A-..M1-..2A-A1/..
34
5.1.3 Waste heat
Ensure that the cooling fins can dissipate waste heat into the environment by free con-
vection.
Observe the following notes to ensure optimum heat convection:
• Use SEW mounting systems or suitable spacers, e.g.:
– Spacers
– Profiles
– Square pipes
– Mounting plates
– T-beams
– Rails
• Ensure that the cooling fins are not located in a closed hollow space.
• It is essential that a minimum distance of 15 mm (0.59 in) between the highest
cooling fin and the next surface, e.g. a mounting plate, is maintained.
• Avoid heat sources in the immediate proximity of the unit.
5.2 Assembly
Use one of the following mechanical fastening options:
• Mounting with mounting brackets
• Mounting using the through bores
5.2.1 Mounting with mounting brackets
CAUTION
Risk of injury due to protruding parts.
Minor injuries.
• Wear suitable protective gloves.
NOTICE
External force too high.
Damage to the thread or the screw.
• Do not exceed the maximum tightening torque of 3.2 Nm (28 in-lb).
Required material
• “Large bracket mounting set” accessory from SEW‑EURODRIVE (part number
12708305):
– 4 mounting brackets
– 8 M5 × 8 studs
• Holding fixture, e.g. square pipe with an edge length ≤ 32 mm
• Suitable fastening and locking elements, e.g. M6 or M8 screws of suitable length
with washers
20278543/EN – 09/2014