7
Electrical connections
X2011: Motor with brake control
Operating Instructions – MOVIPRO
®
PHC11A-..M1-..2A-A1/..
59
7.9 X2011: Motor with brake control
NOTICE
Damage or malfunction due to motors with built-in brake rectifiers.
Damage to the drive system or its environment.
• You must not use motors with built-in brake rectifiers in conjunction with
MOVIPRO
®
units.
The following table displays information about this connection:
Function
Power connection for motor with brake up to 4.0 kW
Connection type
Han
®
Q 8/0, female
Wiring diagram
9007201696170251
Assignment
No. Name Function
1 U Motor phase U output
2 14 SEW brake terminal 14 (white)
3 W Motor phase W output
4 15 SEW brake terminal 15 (blue)
5 TF/TH/KTY+ Motor temperature sensor (+)
6 13 SEW brake terminal 13 (red)
7 V Motor phase V output
8 TF/TH/KTY- Motor temperature sensor (–)
PE PE PE connection
20278543/EN – 09/2014