10
Service
MOVITRANS® energy supply
Operating Instructions – MOVIPRO
®
PHC11A-..M1-..2A-A1/..
97
10.2 MOVITRANS
®
energy supply
MOVITRAN
S® energy
supply
Also observe the information in the following chapters:
Inspection/maintenance (2 92)
Unit replacement (2 92)
Display (2 93)
Fault information of the frequency inverter (2 93)
Shutdown (2 95)
Storage (2 95)
Waste disposal (2 96)
10.2.1 Extended storage
If the unit is stored for a long time, connect it to the supply voltage for at least 5 mi-
nutes every 4 years. Otherwise, the unit's service life may be reduced.
Procedure when maintenance has been neglected:
Electrolytic capacitors are used in the inverters. They are subject to aging effects
when deenergized. This effect can damage the capacitors if the unit is connected di-
rectly to the nominal voltage after a longer period of storage.
If maintenance has been neglected, SEWEURODRIVE recommends to connect the
unit to a MOVITRANS
®
supply with reduced line cable current. To do so, set the nomi-
nal line cable current parameter in the MOVITRANS
®
supply according to the following
overview to slowly increase the internal voltage supply.
The following stages are recommended:
Stage 1: Power on with 50% of the line cable current
Stage 2: 50% line cable current for 15 minutes
Stage 3: 75% line cable current for 15 minutes
Stage 4: 100% line cable current for 1 hour
20278543/EN – 09/2014