Service
Line connection energy supply
Operating Instructions – MOVIPRO
®
PHC11A-..M1-..2A-A1/..
95
Reset
WARNING
Danger due to unintended motor startup.
Severe or fatal injuries.
Comply with the startup instructions.
Set the controller inhibit.
Switch off the output stage.
Decouple the drive.
Deactivate the auto-reset function for drives that start up automatically.
An error message can be acknowledged by:
Switching the voltage supply off and then on
Always maintain a minimum switch-off time of 1 minute.
Reset using the parameters of the frequency inverter
Reset via the process data interface
Auto reset performs up to 5 unit resets with an adjustable restart time.
10.1.5 Shutdown
To shut down the unit, disconnect it using appropriate measures.
WARNING
Electric shock due to charged capacitors.
Severe or fatal injuries.
Observe a minimum switch-off time after disconnecting the supply system:
10 minutes.
10.1.6 Storage
Observe the following instructions when shutting down or storing the safety controller:
If you shut down and store the unit for a longer period, you must cover the connec-
tions with the protective caps supplied.
Place the unit on a side without connectors during storage.
Make sure that the unit is not subject to mechanical impact during storage.
Connect the unit to the power supply for at least 5 minutes every 2 years.
Observe the notes on storage temperature in chapter "Technical data".
20278543/EN – 09/2014